Why GD&T is hard to plan
A feature control frame packs a lot into one box: the characteristic, the tolerance zone, a material condition modifier and the datum reference frame. Planning it means reading all of that correctly, then choosing how to measure it and what counts as a pass.
How Inspectly reads it
- Every frame is read on every view and sheet, including datums and modifiers.
- Boxed is basic. A basic dimension carries no tolerance of its own; its limits come from the frame that controls it.
- Bracketed is reference. A reference dimension is marked as not inspected, rather than given a made-up tolerance.
- Bonus tolerance at MMC or LMC is calculated by the rule engine, not estimated by the AI.
What a plan line contains
| Field | Example |
|---|---|
| Specification | Position Ø0.25 at MMC to A, B, C |
| Instrument | CMM, or the tool your business rule names |
| Accept criteria | Within Ø0.25 at MMC, plus bonus from the feature's actual size |
| Citation | ASME Y14.5-2018, by section |